Description: CMS5100 patient monitor with NIBP SpO2 PR CMS5100 Patient Monitor adopts Oscillometry for NIBP measuring, Photoelectric Oxyhemoglobin Inspection Technology combining Capacity Pulse Scanning & Recording Technology for SpO2 measuring. Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR) can be accurately measured.Compact appearance, comprehensive functions, simple and convenient operation, which is applicable for hospitals, community medical treatment and family. Features ■Be applicable for adult, pediatric and neonatal for all-round monitoring, easy operation and high cost performance. ■Be applicable for medicine, surgery, operating room, ICU/CCU, emergency room, obstetrics and gynecology, pediatrics. Built-in rechargeable Li-polymer battery for uninterrupted monitoring. ■Compact and flexible appearance, easy for carrying and be suitable for indoor and outdoor(in ambulance) monitoring. ■With user-friendly interface. ■Display with 2.8'' (320×240) color TFT LCD and red and yellow highlight LED. ■Visual and audible alarm for Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR), and upper and lower limit of alarm can be set. ■Unique Flash memory, storage for up to 2000 NIBP data and 30000 SpO2 data. ■Convenient and quick in inquiring measurement data, review for NIBP trend graph within 24-hour and SpO2 and Pulse rate(PR) trend graph within 20-hour. Performance NIBP monitoring ■Measurement method: Oscillometry ■Measurement mode: manual/auto/continuous. ■Auto measurement interval: adjustable from 1 to 90 minutes. ■Resolution: 1mmHg. ■Accuracy: Maximum Mean deviation≤±5mmHg, Maximum Standard deviation≤8mmHg. ■Self-check function. ■Overpressure protection: double protection for software and hardware. Range Adult: Systolic pressure: 40mmHg~270mmHg Mean pressure: 20mmHg~235mmHg Diastolic Pressure: 10mmHg~215mmHg Pediatric: Systolic pressure: 40mmHg~200mmHg Mean pressure: 20mmHg~165mmHg Diastolic Pressure: 10mmHg~150mmHg Neonatal: Systolic pressure: 40mmHg~135mmHg Mean pressure: 20mmHg~110mmHg Diastolic Pressure: 10mmHg~100mmHg Upper and lower limit of alarm Adult: Systolic pressure: 40mmHg~270mmHg Mean pressure: 20mmHg~235mmHg Diastolic Pressure: 10mmHg~215mmHg Pediatric: Systolic pressure: 40mmHg~200mmHg Mean pressure: 20mmHg~165mmHg Diastolic Pressure: 10mmHg~150mmHg Neonatal: Systolic pressure: 40mmHg~135mmHg Mean pressure: 20mmHg~110mmHg Diastolic Pressure: 10mmHg~100mmHg SpO2 monitoring Continuous real-time measuring. Adopt digital SpO2 technology, which has strong anti-interference capability. Real-time display SpO2, pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate(PR) trend graph. Standard finger-clip probe for adult , binding probe for neonatal is optional. SpO2 Measuring Range: 35%~100% (Resolution: 1%) Accuracy: ±2% in stage of 70%-100%, and unspecified in stage of less than 70%. Pulse Rate Measuring Range: 30bpm~250bpm(Resolution: 1bpm) Accuracy: ±2bpm or ±2%, whichever is greater. Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%; the Pulse rate error is ±2bpm or ±2%, whichever is greater. Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%. Accessories A power cord A power adapter A SpO2 probe An adult NIBP cuff An extending tube for blood pressure Physical characteristic Dimension for product: 190(L)×162(W)×240(H)mm Weight: 1.6kg Dimension for packaging: 402(L)×228(W)×320(H)mm Buy safe products The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item. The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of United States and CE,TUV of Europe. The Fingertip Pulse Oximeter that is FDA 510K Approved International Buyer--Please note: Import duties,Taxes are not included in the item price.These charges are buyers' responsibility We are the manufacturer of medical equipment for 17 years, the following are our main products: ECG / ECG holter EEG / EEG Holter B-ultrasound Patient Monitor Fetal doppler Fetal Monitor Spo2 Monitor Stethoscope Medical Image.... Agent in the world! We are look for partners in the world now! Do you want to become our agent in you conutry? Join US! Skype:xuebox3 contec.med.mary at hotmail.com Only English User Manual,Please contact us if you need other language version.thank youThis product is sold worldwide, if you are using it in the United States, please contact me before purchasing
Price: 299 USD
Location: qin huang dao
End Time: 2024-11-22T09:39:54.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money Back
Bundle Listing: Yes
Featured Refinements: Vital Signs Monitor
Model: CMS5100
Country/Region of Manufacture: China
Features: Battery Operated
MPN: 69450401
Brand: CON-TEC